Hydrant
& Automatic sprinkler system
|
|

|
Shows Hydrant Line &
Post |
|

|
Shows Fire Escape Hydrant
at First Floor |
|
|
Shows Cut Off Valve |
|
 |
Shows Hose Box for Hose
Pipe & G.M. Nozzle |
|
|
Shows Fire Hydrant Pu~mp
Room |
|
|
Shows Fire Hydrant Water
Tank |
|
|
|
Dry Hydrant system
:
As shown above system
is designed as per prevailing Insurance rules. In case of fire, same is
to be operated manually.
Automatic wet Hydrant system :
|
This system will be also designed as per regulations & will be
as per above typical layout.
The pipe
net work is always under water pressure. When operated for fire
extinguishing it will immediate feed water supply & main hydrant
pump will be started automatically.
To meet
with minor leakages jockey pump is installed which maintains the
pipe net work under pressure. On drop of pre-set water pressure
due to leakages or any other reason, jockey will operate automatically
& stop at preset pressure.
|
Hydrant
Post Hose Box with
Nozzle & Hosepipe |
|
On actual fire operation jockey pump being of small capacity cannot maintain
the pressure hence main pump will be operated automatically & supply
the rated water quantity to the system.
The system being automatic immediate water supply will be available from
all hydrant post.
Diesel engine
driven hydrant pump
:
|
In case
of uncertainity of power supply or power failure or additional safety
Diesel driven hydrant pump having same capacity of main pump should
be installed.
All the
three pump sets i.e. Main pump, Jockey pump & Diesel driven
pump functioning can be synchronized for automatic operation.
|
Pump
room |
|
Automatic Sprinkler system :
|
Sprinklers |
The system
is designed & installed as per prevailing Insurance rules. The
pipe net work is installed in the area to be protected. Sprinklers
are installed as per regulations at certain intervals. Complete
net work is under water pressure.
In case of fire, glass bulb or the metallic strip of sprinkler melts
& water is automatically spared over the affected area.
|
|
On drop of water pressure in the system the sprinkler pump will operate
automatically to supply the water and mechanically operated gong-bell
gives the alarm.
We under
take
- Turnkey job of installing
above systems
- Extension/Modification
to already installed systems
- Annual service contract
for maintaining the system
- Consultancy & designing
of systems
- Supply of equipment
& their spares
|
|
- Hydrant valves
- Hydrant hoses
- Hose coupling
- Nozzles
- Metallic hose
boxes
- Siamese connection
- Water monitors
- Foam monitors
- All type of fittings
e.g. stop valves, N.R.V.
- FOG Nozzle
|
|